Compact 27 Helix

The Compact 27 is a tubular 8 mm ultrafiltration membrane very well suited for the separation of biological sludge, or any other high solids application (up to 40,000mg/l solids) in which high effluent quality is required. Separating at 0,03 micron, this membrane filter allows only water and dissolved matter to pass, rejecting everything that is undissolved.
Product Number:
7821KRJ99R
Request Price and Availability
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
8.0
Hydraulic membrane diameter [mm]
27
Membrane area [m²]
220.0
Feed connection D0 [mm]
3000
Module length L0 [mm] (±1)
240
Saddle diameter D1 [mm]
213
Module diameter D2[mm]
73,0
Permeate connection d0 [mm]
165
Permeate length I0 [mm] (±1)
90
Permeate position I1[mm] (±1)
Product Number:
7821KRJ99R
Request Price and Availability
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Product Information

General Solvent Resistance

Since the resistance of the membrane to solvents strongly depends on the actual process conditions, the indications given below should only be considered as guidelines

Sodium Hypochlorite

  • Typical 200 ppm, at ≤ 40 ºC
  • Maximum 500 ppm
  • 250.000 ppm hours cumulative at 30 ºC

Operating Specifications


Max. feed pressureMax. permeate pressureMax. transmembrane pressureMax. temp.
[kPa][kPa][kPa][kPa]
20- 60 °C 800at 20 °C 650at 20 °C -60 ~ +50060

at 30 °C 550at 30 °C -60 ~ +500

at 40 °C 450at 40 °C -60 ~ +500
at 50°C 380at 50°C -50 ~ +500
at 60°C 300at 60°C -50 ~ +500

*To avoid mechanical damage, do not subject the membrane module or element to sudden temperature changes, particularly decreasings. Do not exceed 60 °C process temperature. Bring the module or element back to ambient operating temperature slowly (typical value 3°C/min). Failure to adhere to this guideline can result in irreparable damage

Tehnical specifications

Weight Specifications

  • Dry weight of membrane element ca. 40 kg [88 lbs]
  • Membrane element filled with water ca. 100 kg [220 lbs]

Hydraulic membrane diameterCrossflow flow rate (*)Pressure-drop across module (turbulent flow) (**)
[mm][m3 /h][kPa]
8.067.9 x v2.1 x L0 x v1.75

Storage

New membrane modules can be stored as supplied in the original packaging. The membrane elements contain an aqueous preservation solution of glycerine (20wt%) and sodium metabisulfite (1wt%). Membrane modules should be stored in a dry, normally ventilated place, away from sources of heat, ignition and direct sunlight. Store between 0 and 40 °C.

The membrane modules should not be subjected to any freezing temperatures. Shelf life is a maximum of 6 months for unused modules in unopened packaging under correct storage coinditions after transfer of ownership for X-Flow BV to the Client. After the maximum period of 6 months all warrantees are null and void unless otherwise agreed in writing between the parties. After use, the UF membrane modules need to be stored wet at all times. To avoid biological growth during shutdowns or storage, wet membranes could be treated with a compatible biocide.

The membrane is compatible with many common disinfecting agents or biocidal preservatives.To avoid biological growth during shutdowns or storage, wet membranes should be treated with a compatible biocide. The membrane is compatible with many common disinfecting agents or biocidal preservatives. For short-term shutdowns, a daily flush with permeate quality water containing up to 2.0 ppm free available chlorine for 30 to 60 minutes may be adequate for bacteria control. In case of long-term storage, membranes should be cleaned before the disinfection step is carried out.

For disinfection, a 0.5% sodium metabisulfite solution can be used. In either situation, modules should be stored hydraulically filled. In case of long-term storage (>7 days), membranes should be disinfected. The membranes should be cleaned using a CEB before the disinfection step is carried out. For disinfection, a 0,5% sodium metabisulfite solution can be used.

In both short and long term storage situations, the modules should remain filled with storage solution.

Connect with Our Expert Engineers Today and Find Solutions for Your Wastewater Challenges

24/7 availability for critical support