MICRODYN RO 8040-BW-400

Spiral-wound brackish water reverse osmosis for water purification and direct replacement applications.
Product Number:
8040-BW-400
Request Price and Availability
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Not specified
Hydraulic membrane diameter [mm]
37.2
Membrane area [m²]
Not specified
Feed connection D0 [mm]
1,016
Module length L0 [mm] (±1)
Not specified
Saddle diameter D1 [mm]
201
Module diameter D2[mm]
28.6 ID
Permeate connection d0 [mm]
Not specified
Permeate length I0 [mm] (±1)
Not specified
Permeate position I1[mm] (±1)
Product Number:
8040-BW-400
Request Price and Availability
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

MANN+HUMMEL · High rejection brackish water reverse osmosis

Product Information

Representative manufacturer photo of an 8-inch fiberglass spiral element. The exact 8040-BW-400 model is not identified in the supplied photo.
Representative manufacturer photo of an 8-inch fiberglass spiral element. The exact 8040-BW-400 model is not identified in the supplied photo.

Dimensional notes: Element dimensions follow the manufacturer's drawing: A is length and B is diameter. Permeate tube dimension C is the outer diameter for male tubes and inner diameter for female tubes. No ±1 mm dimensional tolerance is stated in the supplied datasheet.

Spiral-wound brackish water reverse osmosis for water purification and direct replacement applications.

Membrane & element specifications

ParameterSpecification
Membrane chemistryThin-film composite polyamide
ConstructionSpiral-wound membrane element
OuterwrapFiberglass
Permeate flow — m³/day (GPD)41.6 (11,000)
Membrane area — m² (ft²)37.2 (400)
Stabilized salt rejection99.6%
Minimum salt rejection99.4%

Performance test conditions: 1,500 ppm NaCl, 15.5 bar (225 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown.

Operating parameters

ParameterSpecification
Maximum operating pressure41 bar (600 psi)
Maximum operating temperature45°C (113°F)
Cleaning pH range1.0 - 12.0
Chlorine tolerance< 0.1 ppm
Maximum pressure drop1 bar (15 psi) per element; 4 bar (60 psi) per housing
Maximum SDI₁₅5.0
Maximum turbidity1 NTU

Physical dimensions

ParameterSpecification
Dimension A — mm (in)1,016 (40.0)
Dimension B — mm (in)201 (7.9)
Dimension C — mm (in)28.6 (1.125)
Permeate tubeFemale
Element weight — kg (lb)16 (36)

Important qualifications

  • Flow rates will be no more than 15% below the values shown. Product specifications may change without notice as design revisions occur.
  • All models have diamond-shaped feed spacers.
  • Dimension C is the inner diameter for female elements and the outer diameter for male elements. Male elements have a protruding permeate tube; dimension D is 1.05 in (26.7 mm).
  • Shipping weight depends on packaging material and quantity shipped.
  • Refer to the temperature and pH limits in Membrane Cleaning Guide – Water Application Elements (TSG-C-001).
  • Pretreatment is recommended to remove free chlorine and other oxidizing agents. Contact with polyamide membranes may shorten operating life or cause membrane failure. Oxidation damage is excluded from warranty; refer to Membrane Operating Guide – Recommendations for Water Purification (TSG-O-012).

Start-up, cleaning & storage

Before operation, flush elements for 30 minutes at low pressure and discard permeate during the flush. See Element Start-Up Guide – System Start-Up (TSG-O-005). Clean periodically to ensure proper operation and prevent membrane damage; see Membrane Cleaning Guide – Water Application Elements (TSG-C-001). Store appropriately; see Element Storage Guides (TSG-O-009 & TSG-O-010).

Manufacturer datasheet

microdyn-ro-bw-data-sheet.pdf · Rev. 2602 · Pages 1–3. Specifications and units above follow the supplied manufacturer document.

The co-branded edition adds BioProcessH2O contact details while retaining the manufacturer's technical content.

Download BioProcessH2O datasheet

Original manufacturer PDF

24/7 availability for critical support

Connect with Our Expert Engineers Today and Find Solutions for Your Wastewater Challenges