MANN+HUMMEL · Integrated vacuum-driven ultrafiltration
Product Information

Dimensional notes: Module body length L is 1,175 mm; overall length L1 is 1,369 mm. Diameter D2 is 303 mm; body diameter D is 271.3 mm. Connection dimensions follow the listed coupling sizes. No ±1 mm dimensional tolerance is stated in the supplied datasheet.
A backwashable spiral-wound UF module with open feed channels and an integrated tank design for highly fouling water and wastewater streams.
Membrane & element specifications
| Parameter | Specification |
|---|---|
| Membrane | Ultrafiltration |
| Membrane chemistry | PES |
| Construction | Negative pressure ultrafiltration module |
| Pore size | 0.03 µm |
| Feed channel | 90 mil corrugated |
| Membrane area | 27.4 m² (295 ft²) |
| Operational gross flux range¹ | 25–45 lmh (15–25 gfd) |
| Recommended backwash flux rate | 40–100 lmh (23–58 gfd) |
Operating parameters
| Parameter | Specification |
|---|---|
| Transmembrane pressure range | 0.07–0.7 bar (1–10 psi) |
| Temperature range² | 5–45 °C (41–113 °F) |
| pH range² | 2.0–11.0 |
| Applicable air scour rate | 5.6 Nm³/hr (3.5 scfm) |
| Cleaning chlorine tolerance | 1,000 mg/L |
| Maximum feed TSS¹ | 1,000 mg/L |
| Maximum feed oil and grease¹ | 100 mg/L |
Physical dimensions
| Parameter | Specification |
|---|---|
| L | 1175 mm (46.2 in) |
| L1 | 1369 mm (53.9 in) |
| L2 | 97 mm (3.8 in) |
| D | 271.3 mm (10.7 in) |
| D1 | 60.3 mm (2.4 in) |
| D2 | 303 mm (11.9 in) |
| Dry module weight | 35 kg (76 lbs) |
| Wet module weight | 39 kg (82 lbs) |
| Feed/drain port | 50.8 mm (2 in) DN50 coupling |
| Permeate port | 38.1 mm (1.5 in) DN40 coupling |
| Overflow port | 50.8 mm (2 in) DN50 coupling |
| Air inlet port | 25.4 mm (1 in) MNPT |
Source specification note: The source prints dry weight as 35 kg (76 lbs) and wet weight as 39 kg (82 lbs), and gives flux in paired lmh/gfd values. The paired units are reproduced as printed; confirm them before design or selection.
Important qualifications
- ¹ Depending on feed water quality and operating conditions.
- ² Temperature, pH limits and cleaning procedures are further detailed in the iSep 500+ User Manual.
Start-up, cleaning & storage
The manufacturer recommends an operational sequence incorporating permeate production, backwash, cleaning and module draining. Clean routinely via backwash, chemically enhanced backwash (CEB) and clean-in-place (CIP) to ensure proper operation and prevent membrane damage. Store appropriately to ensure proper operation and prevent membrane damage.
Manufacturer datasheet
iSep500+ UF datasheet.pdf · Rev. 2602 · Pages 1–2. Specifications and units above follow the supplied manufacturer document.
The co-branded edition adds BioProcessH2O contact details while retaining the manufacturer's technical content.
Download BioProcessH2O datasheet