Grand Central Sanitary Landfill enhanced its wastewater treatment with a bioFLOW™ MBR system, increasing capacity, improving effluent quality, and eliminating the need for offsite leachate disposal.

project

bioFLOW™ MBR System for Landfill Leachate

industry

Waste Management

application

Chemical Oxygen Demand (COD) removal & Nitrification | Pretreatment for Reverse Osmosis membrane filtration

Waste Management – Grand Central Sanitary Landfill

Application Parameters

bioprocessH2O is equipped with a team of experts experienced in the wastewater industry. We provide solutions by offering innovative wastewater treatment systems that are custom built to each client’s needs and specifications. Allow bioprocessH2O to help you get the most out of your water with these recommended treatment systems.

Parameter
Influent
Effluent
Wastewater Flow
0.13 MGD
-
BOD
5,500 mg/L
<5 mg/L
Ammonia-N
2,500 mg/L
<1 mg/L
TSS
150 mg/L
<5 mg/L
Inside of a membrane.

The Problem

The Grand Central Sanitary Landfill needed to upgrade the existing Sequencing Batch Reactor (SBR) to a Membrane BioReactor (MBR) to increase treatment capacity, effluent quality, and eliminate pumping & hauling of leachate offsite.

The Solution

bioprocessH2O designed and supplied a bioFLOW™ Ultrafiltration (UF) equipment package that was integrated into the existing site. The existing aeration tanks and ancillary equipment were incorporated into the design.

The Results

The bioFLOW™ MBR System effectively meets all treatment goals and effluent requirements for discharge to the local municipality and eliminates costly pumping & hauling of leachate offsite.

130,000

GPD

>99%

BOD Removed

>99%

Ammonia-N removed